Author
Dr. David Fairhurst, PhD
Background
CELLFOOD is a highly concentrated proprietary liquid formulation comprising
a host of trace elements, minerals, enzymes, amino-acids, solvated (dissolved)
oxygen and deuterated hydrogen. It is sold as a complete mineral and nutritional
supplement to enhance the biochemical activities and functions of the body.
It has been suggested (1), based on the anatomy and composition of the CELLFOOD,
that it may be a colloidal suspension functioning in a manner similar to,
and compatible with, body fluids (such as blood, lymph, cerebrospinal, synovial
and bone). The purpose of the present study is to determine the colloidal
nature or behavior, if any, of CELLFOOD. The various mechanisms by which
CELLFOOD may act, as a nutritional supplement, is beyond the scope of this
report.
Introduction
It is, perhaps, instructive, to first define exactly what constitutes "the
colloidal state" and why such systems - colloids - are so important.
The overwhelming majority of manufactured products, that we deal with on
a day-to-day basis involve, either in the final state or at some stage of
their production, suspensions of particulate materials, emulsion droplets
or air bubbles dispersed often at high volume fraction. Any suspension may
exist in three distinct conditions depending upon the degree of subdivision
of the discontinuous (internal) phase. For example, during the hydraulic
transport of a coarsely ground limestone/water slurry through a pipeline,
we can determine the technologically important physical properties of the
system from the bulk properties of the separate phases and also by application
of appropriate laws of mechanics and hydraulics; the chemical composition
of the phases, as such, is unimportant. If, however, the same limestone-water
mixture is subjected to grinding to reduce the particle size to below one
micrometer (10-6m), the system takes on characteristics unpredicted by the
laws that previously applied. The suspension may behave as a semi-solid paste
or as a free-flowing liquid depending, now, upon the presence of trace amounts
of certain dissolved electrolytes that have no discernable effect on the
original mixture. Further reduction of particle size to atomic/molecular
dimensions, (say by dissolving with hydrochloric acid) will yield a system
with behavior characteristic of liquid phases, i.e. a solution.
It is the intermediate systems - termed colloidal dispersions - that are
of special interest because of their unique properties. But first, how, then,
do we define the colloidal-size range? As a very rough guide, colloidal-sized
particles lie within the range of one or two nanometers (10-9m) to a few
micrometers, i.e. from about the size of lactoglobulin to about the size
of a small bacterium (such as staphylococcus). The red blood cell is about
seven micrometers in diameter and is treated as a colloidal dispersion (2)
and has long been used as a calibration reference material (3). Hence, while
the lower size limit, at which we differentiate between a colloidal particle
and a dissolved molecule, is understandably vague; the upper size limit is
annoyingly arbitrary!
The colloidal domain, therefore, forms a critical interface between micro-
and macroscopic regimes; it has been termed "the place where physics, chemistry,
biology and technology meet" (4). The essential character common to every
colloidal system is the large area-to-volume ratio for the particles involved
(5). This can result in exceptional catalytic activity and chemical/biochemical
reactivity; it directly impacts biomedical processes in, for example, controlled
release of drugs after digestion, inhalation etc. The efficacy of such systems
is dependent on the actual particle size distribution (PSD) of the particles
and the chemical composition of the suspending fluid (6); this determines
whether or not the particles will adsorb at, or permeate, a cell membrane
(a phopholipid bilayer). From this it can be readily appreciated that not
every colloidal system is "beneficial". For example, natural water contains
dissolved organic carbon (DOC), arising from the microbial and photolytic
degradation of natural organic matter (NOM), creating, in effect, organic
pollutants in the form of a colloidal dispersion. Current water treatment
processes can remove only about 50% of NOM - a cause for concern by the World
Health Organization. On a positive note, in recent times, the advent of "nanotechnology" has created excitement in a wide array of sectors in the
scientific, medical and financial communities. Yet nanoscale materials are,
by definition, colloidal systems.
Sample Preparation and Measurement
When any material is dispersed in a fluid, the properties of the resultant
suspension are dependent upon two fundamental parameters, namely:
(i) The extent of the particle-fluid interface. This is characterized by
properties such as the particle size/particle size distribution and particle
shape and porosity, and
(ii) The particle-fluid interfacial chemistry. This is characterized by the
type and the degree of dissociation of any material surface functional groups
in relation to the fluid chemical composition
There are many parameters that can be measured which reflect the extent of
the interface and the interfacial chemistry. Two reliable and well-established
parameters are, respectively, particle size and zeta potential; the techniques,
that have been devised to determine them, are extremely diverse (7-9). The
present study utilized an instrument based on dynamic light scattering for
particle size measurement and phase analysis light scattering (10) for
determination of the zeta potential. All measurements were conducted by
Mr.William Bernt (Particle Characterization Laboratories, Novato, CA) using
a ZetaPALS instrument with the Particle Sizing Option (Brookhaven Instruments
Corporation, NY).
Particle Size Analysis: The CELLFOOD concentrate was diluted using DI (VWR
18Mohm) water that had been filtered through a 0.1mm filter. The instrument
was validated using a 92nm (+/- 3.7nm) PS latex suspension (NIST traceable)
obtained from Duke Scientific, CA). The filtered DI water was also measured
as a blank.
Zeta Potential Analysis: The CELLFOOD concentrate was measured as received
and also diluted using DI (VWR 18Mohm) water. The instrument was validated
using an NIST electrophoresis reference (SRM 1980) of 2.53 +/- 0.12 mobility
units (equivalent to a zeta potential of 32.4 +/- 1.5 mV).
Results and Discussion
The particle size results of the instrument validation and test sample are
given in the Bernt (PCL) Report of May 14, 2001. The filtered DI water produced
random scatter in the correlation function and a count rate too low for any
analysis, consistent with the absence of any particles in the water. For
the validation sample, it is clear from all methods of analysis of the raw
data (Cumulants, NNLS and CONTIN) that the instrument passes validation.
The particle size distribution (PSD) is clearly a narrow unimodal as shown
by the polydispersity index of <0.01. The overall average particle size
(PS), from all data, was calculated to be 91.2nm, well within specification.
Colloidal systems are generally, however, of a polydisperse nature, i.e.
the particles in a particular sample vary in size and CELLFOOD is no exception.
The method of cumulants gives an average PS of 2.45 mm and the polydispersity
index of 0.322 suggests a very broad PSD. This was confirmed by the NNLS
and CONTIN analysis and, in addition, both algorithms resulted in a bimodal
distribution with modal sizes at approximately 1.48 mm and 6.63 mm. Such
a PSD is entirely consistent with the extremely complex compositional nature
of CELLFOOD and the shape would, of necessity, impart unusual performance
characteristics.
The zeta potential results of the instrument validation and test samples
are given in the Bernt (PCL) Reports of May 15, 2001 and February 23, 2002.
The filtered DI water had a measured conductance of 9 mS, as might be expected
and, since the particle size analysis did not detect any particles it is
also not surprising that the measured zeta potential was close to zero (0.03mV).
The instrument passed validation: the (average) measured conductance of the
electrophoresis reference suspension was 1469 mS and an average calculated
zeta potential of 32.1mV - both values within specification.
The first test sample was the CELLFOOD concentrate run without dilution.
The measured conductance was an amazing 200,000 mS, undoubtedly due to the
very high concentration of electrolytes in the composition. The zeta potential
was calculated to be -22.7mV, consistent with the fact that, under normal
circumstances, biological cells tend to carry a net negative surface charge
(or zeta potential). For example red blood cells suspended in isotonic saline
solution (essentially 0.145 molar NaCl) have a measured zeta potential of
approximately -14mV. Typically, micro-organisms have zeta potentials in the
range of -5 to -15 mV. Now, the magnitude of the zeta potential always
"decreases" (i.e., in this case, becomes less negative) with increase in
electrolyte concentration. The conductance of the CELLFOOD concentrate is
however, considerably larger than that for isotonic saline and yet the zeta
potential is more negative. This is very unusual and it suggests that the
colloidal particles in CELLFOOD may possess very special properties that
could influence metabolic changes or alterations in blood flow properties
and increase absorption of components from body fluids. It is well accepted
that the magnitude and sign of the charge on a biological surface will influence
its interaction with other surfaces or molecules.
The second test sample was the CELLFOOD concentrate diluted into filtered
DI water at the rate of 8 drops to 8oz identical with the recommended daily
dosage. As expected, the conductance now decreased to around 3500 mS. However,
the zeta potential hardly changed. Indeed, it decreased slightly to -20 mV,
when it should have increased (i.e. become more negative). It is not possible,
at this time, to speculate on why this should occur because the composition
of the CELLFOOD is so complex. However, such behavior while desirable, is
very unusual.
It is known that glacial waters contain mineral colloidal particles and a
virtual "soup" of dissolved salts (electrolytes) and that drinking such water
has a very positive benefit on the health and longevity of the users. In
addition, it has been reported that the use of such waters in industrial
formulations (such as cement) seems to dramatically improve performance
characteristics. A detailed analysis of the surface and interfacial properties
of glacial waters was able to substantiate some of the claims (11) even though
the mechanisms involved could not be identified. Although it has not been
possible to carry out a similar in-depth analysis of CELLFOOD, the similarities
in colloidal nature lead this author to conclude that CELLFOOD is indeed,
a very beneficial colloid.
Conclusion
CELLFOOD is clearly colloidal dispersion. The shape of the particle size
distribution and the magnitude of the zeta potential would suggest that the
product would be compatible with body fluids. The data supports the notion
that CELLFOOD should be beneficial as a nutritional supplement.
References
1. D.S. Dyer, "CellFood®: Vital Cellular Nutrition for the New
Millenium",
Feedback Books, (2000).
2. G.V.F. Seaman, "The Red Blood Cell", Academic Press, (1975).
3. D.V. Richmond and D.J. Fisher, in "Advances in Microbial Physiology",
(1973).
4. D.F. Evans and H. Wennerström, "The Colloidal Domain", VCH Publishers,
(1994).
5. D.H.Everett, Basic Principles of Colloid Science, Royal Society of Chemistry
Publications, (1988).
6. R.J. Hunter, "Introduction to Modern Colloid Science", Oxford University
Press, (1993).
7. T.Allen, "Particle Size Analysis Measurement", Chapman & Hall, (1993)
8. D.J.Shaw, "Electrophorsesis", Academic Press, (1969).
9. P.McFadyen and D. Fairhurst, in "Nanoceramics" (ed. R.Freer), British
Ceramic Society, (1993)
10. W.W. Tscharnuter and D. Fairhurst,, ACS Symposium Series
11. B. Marlow and D. Fairhurst, unpublished results/ Univ. Mass. Internal
report